NEST Cell Culture Inserts, Sterile Test Plates + Inserts with PET Membrane, for Cell Culture, Non-Treated
Upon request
Summary
- Available variants of multi-well plates: 6-well, 12-well, 24-well complete with inserts
- Membrane: PET (Polyethylene Terephthalate, Polyester) – high transparency, low protein adsorption, ideal for precise microscopic analyses and transport studies
- Available pore diameters in inserts: 0,4 μm, 1,0 μm, 3,0 μm, 8,0 μm (for applications such as transport, migration, cell invasion)
- High pore homogeneity and constant permeability ensuring high experimental reproducibility
- Material of construction: 100% virgin high-clear polystyrene, USP class VI
- Surface Non-Treated — unmodified, with properties similar to native polystyrene; leaves the user complete freedom in selecting coatings (e.g. ECM proteins) or using lower cell adhesion
- Design compatible with automation systems and most dyeing and fixing solutions
- Low protein binding and low analytical interference due to the PET membrane with minimal autofluorescence
- Each batch is marked with a batch number for full traceability
- Designed for cell models including Caco-2, MDCK, endotheliocytes, immune cells, and lines used in migration and invasion assays
- Suitable for applications: transport and permeation, co-culture, cytotoxicity studies, migration assays, angiogenesis, chemotaxis
- Full automation of production and clean room conditions
- E-Beam Sterilization, SAL 10⁻⁶
- High protection against cross-contamination
- Sterile, non-pyrogenic, non-cytotoxic, free of DNase, RNase and human DNA
- Certified RNase-, DNase- and Pyrogen free
- Medical device for In Vitro diagnostics in accordance with Regulation 2017/746 (hereinafter: IVDR)
ORDER - SELECTED VARIANTS
NEST Cell Culture Inserts Sterile Test Plates – PET Membrane, TC-Treated
NEST Cell Culture Inserts with membrane PET (polyester) and surface TC-Treated are professional cell culture systems designed for studies of cell transport, migration, invasion, and polarization. The inserts are integrated with 6-well, 12-well, and 24-well plates, and are also available in a 100 mm vessel configuration, making it easy to match the format to the scale and type of experiment and integrate with typical laboratory equipment. Accessories from the section are ideal for everyday use. pipetting and dosing, including NEST serological pipettes, which facilitate rapid and sterile medium administration. The PET membrane is distinguished by its excellent transparency and high optical clarity, facilitating the observation of cell morphology and condition under brightfield and fluorescence microscopy, while low protein binding facilitates reproducible results in transport and cytotoxicity assays.
PET membrane and TC-Treated surface – technical parameters and quality
Various pore diameters of PET membrane are available – 0,4 µm, 1,0 µm, 3,0 µm and 8,0 µm – which enables precise model matching to the application: from barrier models (e.g., Caco-2, MDCK) to leukocyte migration, endothelial cell, or cancer cell invasion assays. TC-Treated is modified by vacuum plasma discharge, which gives it a hydrophilic character and a negative surface charge, supporting the adhesion and proliferation of most cell lines and ensuring stable, repeatable culture conditions. To reduce the risk of contamination and work with small volumes, we recommend pipette tips with filter, and when preparing sterile media and buffers they are useful sterile PES filters 0,22 µmThe inserts are individually packaged in Tyvek® blisters with a tear-off lid, sterilized using the E-Beam (SAL 10⁻⁶) and manufactured from transparent, virgin polystyrene grade USP VI; are free from DNase, RNase and pyrogens, and the batch number ensures full traceability of each batch.
Research Applications and Compatibility with Googlabsci Accessories
NEST Cell Culture Inserts PET, TC-Treated are ideal for epithelial and endothelial barrier models (compound transport and permeation, ADME), co-cultures and cell differentiation studies, tumor cell migration and invasion assays, angiogenesis and chemotaxis, and cytotoxicity and compound secretion studies. The high transparency of the membrane and compatibility with fixation and staining solvents allow for easy integration of the inserts into typical immunocytochemistry and image analysis protocols. To maintain consistent dispensing precision (especially in batch work and automation plans), it is worth using automatic pipettes and matching accessories from the category serological pipettes, which additionally increases work safety and repeatability of results.
| Pore density (μm) | 0.4μm, 1.0μm, 3.0μm, 8.0μm |
|---|---|
| Sterile | Yes |
| Degree of cleanliness | DNase/RNase free, Non-Pyrogenic |
| Type of surface | Non-Treated |
| Membrane type | PET |
| pcs/pack | 12 inserts * 4 plates / 48 inserts, 24 inserts * 2 plates / 48 inserts, 6 inserts * 4 plates / 24 inserts |